NONLINEAR RESPONSE OF ACID STORAGE TANK COUPLED WITH PIPING ATTACHMENT UNDER SEISMIC LOAD FOR OPTIMAL SAFE DESIGN
SCOPUS 2025 = 2.4

Indexed: WEB of SCIENCE,
SCOPUS, DOAJ, SCIELO,…
PDF

How to Cite

JOYAA, A. J., HYDERB, M. J., & ZULFIQAR, Y. (2021). NONLINEAR RESPONSE OF ACID STORAGE TANK COUPLED WITH PIPING ATTACHMENT UNDER SEISMIC LOAD FOR OPTIMAL SAFE DESIGN. Latin American Journal of Solids and Structures, 18(1), 1-21. https://doi.org/10.1590/1679-78256301

Abstract

OPTIMUM SAFE DESIGN THROUGH NUMERICALLY INVESTIGATION AND SIMULATION OF FLUID STRUCTURE INTERACTION DUE TO SEISMIC LOADING ON ACID STORAGE TANK WITH PIPING ATTACHMENT IS PRESENTED. THE SEISMIC RESPONSE RELATIVELY DIFFERENT FROM CONVENTIONAL STRUCTURES DUE TO HYDRODYNAMIC FORCES ACTING ON THE TANK SHELL AND PIPE WALLS AND ALSO DUE TO MANY OTHER NONLINEAR FACTORS SUCH AS SLOSHING, FLUID-STRUCTURE INTERACTION, LARGE DEFECTION AND GEOMETRIC NONLINEARTIES. A NONLINEAR FLUID-STRUCTURE INTERACTION BASED ON THE FINITE ELEMENT METHOD IS PERFORMED ON A FULL-SCALE 3D MODEL. INVESTIGATIONS ARE SUPPLEMENTED BY A COMPUTATIONAL FLUID DYNAMIC ANALYSIS TO SIMULATE THE FLUID MOTION INSIDE THE TANK USING FULL-SCALE RESPONSE ACCELERATION TIME HISTORY OF KOCAELI EARTHQUAKE MAGNITUDE 7.4, RESPONSE OF THE MAXIMUM STRESS, DEFORMATION, AND DISPLACEMENT OF PIPING ATTACHMENT FOR RIGIDLY RESTRAINED FIXED AND FLEXIBLE TANKS AT DIFFERENT FLUID FILL LEVELS AND THICKNESS ARE EVALUATED. THE RESULTS ARE COMPARED AND ANALYZED WITH DESIGN CODES AND THE DIFFERENCE OBSERVED IN HYDROSTATIC PRESSURE IS LESS THAN 0.08%, AND THE DIFFERENCES OBSERVED IN MAXIMUM VALUES OF HYDRODYNAMIC PRESSURE ARE LESS THAN 4.3 %, 0.8% AND 1.5% AT THREE FLUID FILL LEVEL WHILE AVERAGE DIFFERENCE IN TRANSIENT TIME HISTORY TOTAL PRESSURE IS LESS THAN 0.4%. FINALLY, THE PROVISION GIVEN IN THE DESIGN CODES AND RESPONSE OF PARAMETERS OF PIPING COUPLED WITH AN ACID STORAGE TANK IS COMPUTED AND A SECOND ORDER POLYNOMIAL CORRELATION IS PROPOSED PER THE MINIMUM REQUIREMENT OF THESE CODES WITH ACCURACY OF ABOVE 0.9999 AND OVERALL AVERAGE DIFFERENCE LESS THAN 5% IN FIXED TANK AND IN FLEXIBLE TANK LESS THAN 2% FOR DESIGNING STORAGE TANK FOR OPTIMAL SAFE DESIGN BY ANALYSIS.

PDF

Authors who publish with this journal agree to the following terms:

 

  1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License [CC BY] that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
  2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
  3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).

Downloads

Download data is not yet available.